Input counter¶
Overview¶
This feature allows counting pulses in a particular pin of an encoder connector (input counter pin).
It counts the transitions on the input counter pin at a maximum frequency of 16 kHz. The value of the counter is written to object 0x2040.
The input counter will be enabled by default in case the configuration allows it (for limitations see below).
Either a single-ended TTL line or a differential RS422 line can be used for the input counter.
Drive |
Conditions for using a Single-ended (TTL) input counter |
Conditions for using a differential (RS422) input counter |
---|---|---|
SOMANET Node |
Encoder connector 2 doesn’t have any encoder configured. Pulses are counted at pin 7. |
Encoder connector 2 has an SSI encoder configured. Pulses are counted at pin 7 (-) and 8 (+). |
SOMANET Circulo 7 and 9 (rev. B.1) |
Digital IO connector is not used for anything else. Pulses are counted at pin 2. |
Not possible. |
Use case: Counting revolutions for simple speed estimation
In applications that run only in one direction (e.g.: a fan), it may be sufficient to count the pulses for calculating the speed.
Limitations¶
At the moment, this feature can only be used if less than 2 encoders are configured or if one of the encoders is an SSI.
If only one SSI encoder is connected (the other port being empty), the feature will use the empty port.
The feature can be used at a maximum frequency of 16 kHz.