0x2208 HALL Sensor 2¶
Configuration parameter for second HALL sensor.
Name | Index:Sub | Type | Bit Size | Options | Unit | Access | PDO Mapping | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Type | 0x2208:1 | USINT | 8 |
|
readwrite | ||||||||||||||||||||
For internal purposes only! |
|||||||||||||||||||||||||
Name | Index:Sub | Type | Bit Size | Options | Unit | Access | PDO Mapping | ||||||||||||||||||
Function | 0x2208:2 | USINT | 8 |
|
readwrite | ||||||||||||||||||||
Determines encoder function/purpose. The encoder can be configured for commutation, motion control feedback and monitoring. In monitoring mode, the position and velocity information will be displayed in objects #0x230A & #0x230B. There is an option to configure two motion sensors, one sensor as a motion position sensor, while the other sensor should have commutation and velocity function. |
|||||||||||||||||||||||||
Name | Index:Sub | Type | Bit Size | Min Data | Max Data | Default Data | Unit | Access | PDO Mapping | ||||||||||||||||
Resolution | 0x2208:3 | UDINT | 32 | 0 | Inc/Revolution | readonly (default) | |||||||||||||||||||
Name | Index:Sub | Type | Bit Size | Min Data | Max Data | Default Data | Unit | Access | PDO Mapping | ||||||||||||||||
Zero velocity threshold | 0x2208:4 | UDINT | 32 | 0 | 5000 | μs | readwrite | ||||||||||||||||||
Time threshold to set the velocity to 0 if no new position was received from the encoder. This variable is currently not used for hall sensor. |
|||||||||||||||||||||||||
Name | Index:Sub | Type | Bit Size | Options | Unit | Access | PDO Mapping | ||||||||||||||||||
Polarity | 0x2208:5 | USINT | 8 |
|
readwrite | ||||||||||||||||||||
Altering the default values is recommended for expert users only! |
|||||||||||||||||||||||||