0x2203 REM 16MT Encoder¶
Configuration parameter for REM 16MT encoder
Name | Index:Sub | Type | Bit Size | Options | Unit | Access | PDO Mapping | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Type | 0x2203:1 | USINT | 8 |
|
readwrite | ||||||||||||||||||||||
For internal purposes only! |
|||||||||||||||||||||||||||
Name | Index:Sub | Type | Bit Size | Options | Unit | Access | PDO Mapping | ||||||||||||||||||||
Function | 0x2203:2 | USINT | 8 |
|
readwrite | ||||||||||||||||||||||
Determines encoder function/purpose. The encoder can be configured for commutation, motion control feedback and monitoring. In monitoring mode, the position and velocity information will be displayed in objects #0x230A & #0x230B. |
|||||||||||||||||||||||||||
Name | Index:Sub | Type | Bit Size | Min Data | Max Data | Default Data | Unit | Access | PDO Mapping | ||||||||||||||||||
Resolution | 0x2203:3 | UDINT | 32 | 65536 | Inc/Revolution | readonly (default) | |||||||||||||||||||||
The total number of increments (positions) per revolution for the REM 16MT encoder is 65536. This parameter is pre-configured. |
|||||||||||||||||||||||||||
Name | Index:Sub | Type | Bit Size | Min Data | Max Data | Default Data | Unit | Access | PDO Mapping | ||||||||||||||||||
Velocity calculation period | 0x2203:4 | UINT | 16 | 66 | 1000 | μs | readwrite | ||||||||||||||||||||
The time period between two position samples. This value is used to calculate the velocity. |
|||||||||||||||||||||||||||
Name | Index:Sub | Type | Bit Size | Options | Unit | Access | PDO Mapping | ||||||||||||||||||||
Polarity | 0x2203:5 | USINT | 8 |
|
readwrite | ||||||||||||||||||||||
Altering the default values is recommended for expert users only! |
|||||||||||||||||||||||||||
Name | Index:Sub | Type | Bit Size | Options | Unit | Access | PDO Mapping | ||||||||||||||||||||
Filter | 0x2203:6 | USINT | 8 |
|
readwrite | ||||||||||||||||||||||
The filter with strength F of the sensor. The estimated step response time of the filter is Ts*2^F (Ts is the sampling time, ca. 70µs). |
|||||||||||||||||||||||||||