Selecting and switching the Modes

Selection of these modes is done by setting the object 0x6060 to the corresponding value as defined in the CiA 402 standard.

The modes are called by setting the object 0x6060 as follows:

Value for 0x6060

Control Mode

+1

Profile position mode

+3

Profile velocity mode

+4

Torque profile mode

+6

Homing mode

+8

Cyclic Syncronous Position Mode

+9

Cyclic Syncronous Velocity Mode

+10

Cyclic Syncronous Torque Mode

Use this object to select the desired Mode